IX Series Metering Pump

IX Series Metering Pumps are digitally controlled direct-drive diaphragm pumps. Years of experience in high-end motor technology result in extremely accurate and energy efficient metering pumps with high resolution. The IX Series meets today’s demand for automated chemical delivery in industries from water treatment to chemical process. Highly precise control offers a solution for a variety of dosing applications. Standard with several control methods, the IX Series pumps provide a solution to a variety of applications all in one pump.

1 – DRIVE UNIT/PUMP SIZE

B007: 1.98 GPH (7.5 LPH)
B015: 3.96 GPH (15 LPH)
B030: 7.90 GPH (30 LPH)
B045: 11.80 GPH (45 LPH)
C060: 15.8 GPH (60 LPH)
C150: 39.6 GPH (150 LPH)
D150: 39.6 GPH (150 LPH)
D300: 79.2 GPH (300 LPH)

2 – WET END MATERIALS

TC = PVDF/FKM/CE
TE = PVDF/EPDM/CE
S6 = 316SS/PTFE

3 – CONNECTIONS

T = Tubing (IXB TC/TE ONLY)
N = MNPT (3/8” FNPT on IX-BS6)
FA = Flange (ANSI 150 lb)

4 – CONTROLLER LOCATION

IX-C/D Only; Leave Blank for IX-B
TB = Top Back
TF = Top Front
TR = Top Right
TL = Top Left
RF = Right Face*
LF = Left Face*
* No display cover on IX-C

5 – POWER CORD

U = USA (115V)
2 = USA (230V)
E = Europe (220V DIN)

CAPACITY/PRESSURE RATING

*CAUTION: Pump may be capable of higher pressure than tubing. Operate pumps at pressures lower than tubing specifications

NOTES:

  • Maximum discharge capacity is rated with clean water at ambient temperature at maximum discharge pressure. Output may increase as pressure decreases.
  • Accuracy is not guaranteed at flows below 0.5GPH (2 LPH) for IX-D300S6, 0.26GPH (1 LPH) for IX-C150S6 or 0.11GPH (0.4 LPH) for IX-C060S6.
  • Maximum viscosity: IX-C: 1000 cps IX-D: 300 cps (standard pumps – consult factory for higher viscosities). Outputs may be reduced.
  • Liquid temperature range: 0 -50°C (TC, TE type), 0-80°C (S6 type). No viscosity change. Non freezing. No slurry.
  • Operating temperature range: 0-50°C (Indoor use only)
  • Operating humidity range: 30-90% RH (Non-condensing in the controller)
  • Maximum dry suction lift rating is 6.5 ft. (2m).
  • Pumps should always be shielded from direct exposure to the elements.

LIQUID END MATERIALS

Material Abbreviations:
PVDF – Polyvinylidene Fluoride (similar to Kynar)
316SS – 316 Stainless Steel
CE – Alumina (Al₂O₃) Ceramic
PTFE – Polytetrafluoroethylene (similar to Teflon)
FKM – Fluoroelastomer (similar to Viton type A)
EPDM – Ethylene Propylene Diene Monomer Rubber