Search walchem.com
 
       
IX Series

IX Series Metering Pumps

 

Links

 
750:1 Turndown Ratio ±1% High Accuracy 70% Energy Savings

 

IX Pump
  • Motor control adjusts the discharge and suction speeds to meet a full and accurate turndown ratio of 750:1 (300 L/h to 200 mL/h)
  • Maintains accurate flow rates allowing a low cost, mechanically-driven diaphragm pump to achieve a high accuracy of ±1%.
  • Helical gears and return springs reduce power consumption by up to 70% compared to conventional motor-driven mechanical diaphragm metering pumps.
  • Fixed stroke length maintains a high compression ratio in each stroke resulting in fast priming and no air-lock at any flow rate.
  • Controller position can be ordered in 6 positions for operator convenience and ease of use after installation.
 
 
 

This document requires Adobe Reader Brochure
This document requires Adobe Reader IX-C Manual (1st generation)
This document requires Adobe Reader IX-C Manual (2nd Generation)
This document requires Adobe Reader IX-D Manual
Go to Exploded Views Exploded Views and Components
IX Video
Go to Tech Support Tech Support
 
Model Max Capacity GPH (LPH) Max Pressure PSI (MPa) Average Power Consumption Current Amps Connection Size Weight
LBS (KG)
IX-C060TC/TE 0.02 - 15.6
(0.08 - 60)
145 (1.0) 62W 0.8A 1/2" NPT 19.9 (9.0)
IX-C060S6 26.4 (12.0)
IX-C150TC/TE 0.05 - 39.6
(0.2 - 150)
58 (0.4) 3/4" NPT 19.9 (9.0)
IX-C150S6 28.6 (13.0)
IX-D150TC/TE 0.5-39.6
(0.2-150)
145 (1.0) 110W 1.3A 3/4" NPT 31.9 (14.5)
IX-D150S6 33.0 (15.0)
IX-D300TC/TE 0.1-79.2
(0.4-300)
73 (0.5) 1" NPT 34.1 (15.5)
IX-D300S6 37.4 (17.0)
  • Maximum viscosity :IX-C: 1000 cps IX-D: 300 cps (standard pumps - consult factory for higher viscosities)
  • Maximum discharge capacity is rated with clean water at ambient temperature at maximum discharge pressure. Output may
    increase as pressure decreases.
  • Liquid temperature range: 0 -50°C (TC, TE type), 0-80°C (S6 type). No viscosity change. Non freezing. No slurry.
  • Operating temperature range: 0-50°C (Indoor use only)
  • Operating humidity range: 0-90% RH (Non-condensing in the controller)
  • Maximum dry suction lift is 6.5 ft. (2m).
  • Accuracy is not guaranteed at flows below 0.5GPH (2 LPH) for IX-D300S6, 0.26GPH (1 LPH) for IX-C150S6 or
    0.11GPH (0.4 LPH) for IX-C060S6.
  • Pumps should always be shielded from direct exposure to the elements